Page 1 - PELLETS STOVES

PELLETS STOVESUse and maintenance manualBELLADIVINAECOLOGICA IDROECOLOGICAI.C. MAXIBABYFIAMMA PREZIOSABELLA LUX CONTESSAI.C. MINIEnglish

Page 2 - IMPORTANT

10TECHNICAL SPECIFICATIONSAll a.m. data are not binding, but valid just as an indication.the right to make technical modifications for improving the p

Page 3 - Contents

11Combustion always requires air (oxygen). Stoves therefore remove air from the room they areinstalled in and this must be replaced.Bad combustion can

Page 4 - 1 PRECAUTIONS AND SAFETY

12The pellets are made by applying very highpressure to sawdust, that is pure timber waste(without paint), produced by sawmills, carpentryworks and ot

Page 5 - 2 TECHNICAL SPECIFICATIONS

135.1 Warm air distribution fan breakdown:If the fan stops for any reason, the stove stops automatically to prevent overheating.5.2 Fume extractor bre

Page 6

146.1 AssemblyAn authorised dealer should assemble thestove.The assembling of the ceramics in the stoveswhich have majolica tiles, must be done by a q

Page 7 - I.C. Maxi

156.3 Fume exhaustIn conformity with DPR 412 and UNI7129-2001, the allowed installations are:WITH VERTICAL EXTERNAL OR INTERNALFLUE• The Fig. 3 repre

Page 8 - FUMES OUTLET PIPE ø 50

16If the fume flue is installed in a fixed way , inspections should be provided for internalcleaning purposes (ashes), especially in the horizontal se

Page 9 - TECHNICAL SPECIFICATIONS

177 INSTALLATION I.C.MAXI and I.C. MINIThe Comfort insert is supplied with a sliding base iniron which allows it to be installed in a pre-existingfire

Page 10 - B: AIR INTAKE PIPE Ø 50

1818fig. 11Finally, using the provided socket wrench, turn thescrew anticlockwise as shown in figure 11.In order to see if the insert is correctly cou

Page 11 - 3 AIR REQUIRED FOR COMBUSTION

19N.B. The hopper support can be fitted on bothsides of the insert Comfort Maxi while for theComfort Mini it can be fitted only on the right side. Adj

Page 12 - 4 WHAT ARE PELLETS ?

2Congratulations! You are now the owner of an EXTRA FLAME stove !The pellet stove EXTRA FLAME is an ideal heating solution. It springs from the most a

Page 13 - 5 SAFETY DEVICES

2020Air circulation ductsIt is necessary to create air intakes on the top of thefireplace for a correct operation.These can be made in the sides of t

Page 14 - *see fig. 4

21For a correct and safe operation of the insert Comfort, you have, during the construction of the fireplace,respect the measures (Fig.17) between ins

Page 15 - EXTERIOR

2222As far as the air inlet box is concerned, there is thepossibility to connect the air inlet pipe above the slidingbase (see pict.18) or under the s

Page 16 - Height over

23231. ON/OFF BUTTONThe stove can be turned on and off automatically by pressing button 1.2-3 SETTING THE TEMPERATURE AND TIMER-THERMOSTATThe buttons

Page 17

24249 USEThe stove you have purchased uses pellets as fuel. This type of material is produced from natural wastefrom woodworking. Using a special proc

Page 18 - Description of components:

2510 LIGHTING1. Check that the hopper is loaded, that the combustion chamber is clean, that the glass door isclosed, that the power socket is connecte

Page 19 - Frames fitting

2611.4 Remote controlThe heating power, the desired roomtemperature and automaticstarting/stopping of the stove can beadjusted by means of the remote

Page 20 - Air circulation ducts

27To light the stove, press both buttons P3 and P5 at the same time for 3 seconds (fig. 21); the stove willautomatically enter the starting stage and

Page 21

2812.2 Mechanical thermostat (optional)There is the possibility to put a thermostat in the room besides the installed stove: it is enough toconnect a

Page 22 - Put high temperature

29Electric drawing Ecologica - Babyfiamma - Preziosa - Divina - Bella - Bella Lux - ContessaElectric drawing I.C. MAXI and I.C. MINIAMBIENT TEMPERATUR

Page 23 - 8 CONTROL PANEL

3ContentsIMPORTANT ... 21 PRECAUTIONS

Page 24 - BASIC INSTRUCTIONS

Display D1Display D2FunctionChronothermostatDAY-NIGHT TEMPERATURE FUNCTIONPELLETS LOADING SETTINGCANALISATION FAN PARAMETERS (DIVINA PLUS)Start/Stop c

Page 25 - 10 LIGHTING

3113 CHRONOTHERMOSTAT This function enables you to program 2 ignitions and 2 extinctions on all the days of the week.The ignition and extinction times

Page 26 - 3= P3 5= P5

32To stop the chronothermostat, press button 3, and while keeping it pressed, press button 5 on thedisplay. Set the value on D1 on OFF (you acces OFF

Page 27 - Once finished, the batteries

331- LACK OF PELLET • The stove cannot develop a suitable flame, tending to burn very low also at high speeds.• At lowest speed, the stove tends to b

Page 28

3413.4 ALARM MESSAGESIf operating faults occur, the stove provides a control system which informs the user on thedisplay where the fault has occurred.

Page 29

3514. Operation description of the radiofrequency bi-directional remote control with LCD displayfor the model INSERTO COMFORT MINI1. GENERAL DESCRIPTI

Page 30 - ELECTRONIC

363. THE DISPLAYThe display LCD by 32 characters located on 4 lines by 8 characters each and 16 bars. The dis-playing of the display changes according

Page 31 - 13 CHRONOTHERMOSTAT

374. USER’S MENUIn this table we list all various menus available for the user:Here below we indicate a list to access to the various user's menu

Page 32

38We indicate here below the meaning of some parameters.Parameter 1:According to the type of application and use made by the user, such a parameter is

Page 33 - OF PELLET

394.4 DAY/NIGHT MENU The day-night temperature function allows to start and switch OFF in automatic way theequipment according to the two temperatures

Page 34 - 13.4 ALARM MESSAGES

41 PRECAUTIONS AND SAFETY The stoves manufactured in our works are builtwith the maximum dedication to the individualcomponents so as to protect both

Page 35

40FUEL LACKFUEL EXCESSIncrease the percentage value of 5 points and test the stove with the newcalibration. If the problem is reduced but not solved,

Page 36 - 33°C Po 1

41ATTENTION: All cleaning and maintenance operations must be carried out when the stoveis completely cold.All herewith described operations are very i

Page 37 - START SCREEN

42fig. 24fig. 23fig. 2215.1 Cleaning Ecologica-I.C.MAXI- Ecol.Idro1 The ash tray must be emptied whenevernecessary. When you carry out this opera-tion

Page 38

43d) If the interior is dirty, use the equipped tool toscrape the deposited ashes and then removethem by using a vacuum cleaner (Fig.26).Insert the mo

Page 39

44fig. 34fig. 33fig. 32fig. 3115.2 CLEANING BELLA- BELLA LUX-DIVINA CONTESSA – PREZIOSA – BABYFIAMMAThe maintenance operations guarantee acorrect sto

Page 40

453. CLEANING THE HEAT EXCHANGERCleaning the heat exchanger allows you tomaintain a constant heat yield over time.This type of maintenance must be car

Page 41 - 15 CLEANING AND MAINTENANCE

4615.3 CLEANING I.C. MINI1. BURN POT CLEANINGThe burn pot must be cleaned every day.To do so, use the special poker(see part.BFig.38) to scrape off a

Page 42

47The pellets are not fed into the combustion chamber.1. The pellet tank is empty2. The fume extractor, the warm airventilator, the feed screw or them

Page 43

48The fire burns a weak orangeflame. The pellets pile up in theburn pot and the door glass getsdirty.1. The air for the combustion isnot enough1.a Che

Page 44

4917 GUARANTEEAll the stoves are guaranteed 24 months.The warranty will be recognised on condition that the purchaser fills in the attached formcompl

Page 45

52 TECHNICAL SPECIFICATIONSAll a.m. data are not binding, but valid just as an indication.The right to make technical modifications for improving the

Page 46 - Inspection

5018 QUALITY CONTROLModelSerial nr.Tests carried out:- Automatic lighting ❏- Combustion air motor ❏- Convection air motor ❏- Aestetic aspect ❏-

Page 47 - PROBLEM REASON SOLUTION

5119 APPENDIX REMOTE CONTROL SENSORD2LED 1D1REMOTE CONTROL SENSORD2LED 1D1CONTROL PANEL Previous versions

Page 48 - PROBLEM REASON SOLUTION

EXTRAFLAME S.p.A.Via dell’Artigianato, 1036030 MONTECCHIO PRECALCINOVicenza - ITALYTel. 0445.864488 (3 linee r.a.)Fax 0445.865243E-mail: info@extrafla

Page 49 - 17 GUARANTEE

6TECHNICAL SPECIFICATIONSAll a.m. data are not binding, but valid just as an indication.The right to make technical modifications for improving the pr

Page 50

7*** Minimum HeightThe detail “ adjustment pipe”is pre-drilled with 3 holes Ø 9 :90-100-90.For other adjustments, drillaccording to needs.A: FUMES OUT

Page 51 - REMOTE CONTROL SENSOR

8TECHNICAL SPECIFICATIONSAll a.m. data are not binding, but valid just as an indication.the right to make technical modifications for improving the pr

Page 52

9TECHNICAL SPECIFICATIONSAll a.m. data are not binding, but valid just as an indication.the right to make technical modifications for improving the pr

Commentaires sur ces manuels